Water Treatment & Environmental

Industrial Wastewater Treatment

Clean water. Compliant discharge. Lower operating costs.

Turnkey Effluent Treatment Plants (ETPs) engineered for electroplating and surface treatment wastewater — from design to commissioning, in compliance with UAE regulations.

What We Treat

EVESS® ETPs are purpose-built for the high-toxicity wastewater generated by electroplating and surface treatment operations. We eliminate all major hazardous contaminant classes:

Heavy Metals

  • Chromium (Cr)
  • Nickel (Ni)
  • Copper (Cu)
  • Zinc (Zn)
  • Cadmium (Cd)

Chemical Contaminants

  • Cyanides
  • Acids
  • Alkalis
  • Other toxic substances
  • Organic contaminants

What We Deliver

Permit Compliance

Treated effluent meets UAE Department of Energy Schedule A limits for all regulated parameters.

Reuse-Ready Water

Closed-loop water return to production processes — reducing freshwater consumption and discharge volume.

Lower Lifecycle Cost

Minimal reagent consumption, lower sludge volumes, and automated operation cut ongoing operational expenses.

Reliable Sludge Management

Dewatered sludge cake produced for controlled, documented disposal by licensed waste handlers.

Advanced Technical Features

  • Electrochemical Cr(VI) reduction without chemical reducing agents
  • Cyanide destruction by electrochemical oxidation
  • Heavy metal precipitation and coagulation
  • Multi-stage pH neutralization and buffering
  • Polymer-assisted flocculation and clarification
  • Belt press or filter press sludge dewatering
  • Membrane or UV polishing for water reuse
  • PLC/SCADA automation with remote diagnostics
  • Online monitoring: pH, ORP, conductivity, turbidity
  • Full instrumentation and alarm management

Regulatory Compliance

UAE Department of Energy (DOE) Schedule A — discharge limits to public sewer

ParameterUAE DOE LimitUnit
pH6.0 – 9.0
COD250mg/L
TSS100mg/L
Total Chromium0.5mg/L
Hexavalent Chromium Cr(VI)0.1mg/L
Nickel0.5mg/L
Copper0.5mg/L
Zinc2.0mg/L
Cadmium0.05mg/L
Cyanide (free)0.2mg/L

EGC Technology — Our Advantage

EVESS® proprietary Electro-Generated Coagulant (EGC) technology enables single-stream treatment of mixed electroplating wastewater — eliminating the need to segregate chromium, cyanide, acid, and alkaline waste streams before treatment. This simplifies plant design, reduces footprint, and lowers operational complexity.

Key EGC Advantages

  • Meets strict UAE regulatory limits without stream segregation
  • Enables water return to production loops (closed-loop capable)
  • Produces lower-toxicity sludge — potential non-hazardous classification
  • Handles wide contaminant spectra including organics and dyes
  • No extra salinity added to treated water
  • Lower chemical reagent consumption than conventional methods

EGC vs Conventional Reagent Method

ParameterEVESS EGC MethodConventional Reagent Method
Stream segregation requiredNo — single streamYes — chromium, cyanide, acid/alkali treated separately
Chromium reductionElectrochemical (no reagents)Reagent-based (sodium bisulfite)
Cyanide destructionElectrochemical oxidationChlorination (hazardous reagent)
Heavy metal removalCoagulation & flocculationPrecipitation (caustic/lime)
Sludge toxicityLower — potential non-hazardousHigher — hazardous classification
Water salinity increaseNoneYes — from added salts
Water reuse potentialHigh — closed-loop capableLimited
Operator complexityLower — automatedHigher — multiple reagent streams
Chemical reagent consumptionMinimalSignificant
UAE DOE Schedule A complianceYesYes (with correct sizing)

Benefits for Your Business

Lower OPEX

Reduced chemical reagent use and automated operation minimize day-to-day operational costs.

Water Reuse

Treated water suitable for return to production loops, reducing freshwater intake and discharge fees.

Compliance Assurance

Systems sized and verified to meet UAE DOE Schedule A — avoiding regulatory risk and penalties.

Reduced Technology Dependence

Locally designed, manufactured, and supported — no reliance on imported proprietary technology.

Delivered Projects

ETP for Zinc Electroplating

Zinc plating line wastewater

Capacity: 0.5 m³/h

  • · pH neutralization
  • · Zinc precipitation
  • · Full automation
  • · Remote diagnostics

ETP for Chromium Plating

Chromium plating line wastewater

Capacity: ~3 m³/h (scalable)

  • · Cr(VI) electrochemical reduction
  • · Chromium precipitation
  • · Full automation
  • · Remote monitoring

Downloads